Patient: VS
VS failed neonatal hearing screening. She was seen at the Nova Southeastern University clinic.
The left 1000 Hz tympanogram was relatively normal; the right shows middle ear mobility reduction / negative pressure.
Click ABRs show no response at 90 dB nHL.
Case donated by Jackie Davie, PhD, Nova Southeastern University